RANCID Config Viewer

Cấu hình: 172.16.14.56

Kích thước: 27,218 bytes | Cập nhật: 2026-04-10 01:11:57

Tải về | Quay lại danh sách

!RANCID-CONTENT-TYPE: cisco ! ! ! ! ! !Image: Boot Image: !Image: NXOS Image: bootflash:///nxos.9.3.13_compact.bin !Image: Active Packages: !Image: Active Base Packages: !Image: bfd-2.0.0.0-9.3.13.lib32_n9000 !Image: bgp-2.0.0.0-9.3.13.lib32_n9000 !Image: dme-2.0.0.0-9.3.13.lib32_n9000 !Image: eigrp-2.0.0.0-9.3.13.lib32_n9000 !Image: ext-eth-2.0.0.0-9.3.13.lib32_n9000 !Image: fhrp-2.0.0.0-9.3.13.lib32_n9000 !Image: isis-2.0.0.0-9.3.13.lib32_n9000 !Image: lacp-2.0.0.0-9.3.13.lib32_n9000 !Image: libnxsdk-2.0.0.0-9.3.13.lib32_n9000 !Image: lldp-2.0.0.0-9.3.13.lib32_n9000 !Image: mcast-2.0.0.0-9.3.13.lib32_n9000 !Image: mpls-2.0.0.0-9.3.13.lib32_n9000 !Image: nbproxy-2.0.0.0-9.3.13.lib32_n9000 !Image: ntp-2.0.0.0-9.3.13.lib32_n9000 !Image: nxos-ssh-2.0.0.0-9.3.13.lib32_n9000 !Image: nxsdk-2.0.0.0-9.3.13.lib32_n9000 !Image: ospf-2.0.0.0-9.3.13.lib32_n9000 !Image: rip-2.0.0.0-9.3.13.lib32_n9000 !Image: sdaa-2.0.0.0-9.3.13.lib32_n9000 !Image: services-2.0.0.0-9.3.13.lib32_n9000 !Image: snmp-2.0.0.0-9.3.13.lib32_n9000 !Image: sr-2.0.0.0-9.3.13.lib32_n9000 !Image: svi-2.0.0.0-9.3.13.lib32_n9000 !Image: tacacs-2.0.0.0-9.3.13.lib32_n9000 !Image: virtualization-2.0.0.0-9.3.13.lib32_n9000 !Image: vtp-2.0.0.0-9.3.13.lib32_n9000 !Image: vxlan-2.0.0.0-9.3.13.lib32_n9000 ! ! ! ! ! !BootFlash: Current Boot Variables: !BootFlash: sup-1 !BootFlash: NXOS variable = bootflash:/nxos.9.3.13_compact.bin !BootFlash: Boot POAP Disabled !BootFlash: Boot Variables on next reload: !BootFlash: sup-1 !BootFlash: NXOS variable = bootflash:/nxos.9.3.13_compact.bin !BootFlash: Boot POAP Disabled ! !BootFlash: % Invalid command at '^' marker. ! !BootFlash: % Invalid command at '^' marker. ! ! % Invalid command at '^' marker. ! ! license1.lic: ! SERVER this_host ANY ! VENDOR cisco ! FEATURE LAN_BASE_SERVICES_PKG cisco 1.0 permanent uncounted \ ! VENDOR_STRING=<LIC_SOURCE>NEXUS_SWIFT</LIC_SOURCE><SKU>N3K-C3048-BAS1K9=</SKU> \ ! HOSTID=VDH=FOC1717R1K3 \ ! NOTICE="<LicFileID>20220818083909904</LicFileID><LicLineID>1</LicLineID> \ ! <PAK></PAK>" SIGN=E12293CC4120 ! license2.lic: ! SERVER this_host ANY ! VENDOR cisco ! FEATURE LAN_ENTERPRISE_SERVICES_PKG cisco 1.0 permanent uncounted \ ! VENDOR_STRING=<LIC_SOURCE>NEXUS_SWIFT</LIC_SOURCE><SKU>N3K-C3048-LAN1K9=</SKU> \ ! HOSTID=VDH=FOC1717R1K3 \ ! NOTICE="<LicFileID>20220818083730901</LicFileID><LicLineID>1</LicLineID> \ ! <PAK></PAK>" SIGN=9BD8520691AA ! ! % Invalid command at '^' marker. ! ! % Invalid command at '^' marker. ! !Flash: % Invalid command at '^' marker. ! !Flash: nvram: % Invalid command at '^' marker. ! !Flash: bootflash: % Invalid command at '^' marker. ! !Flash: slot0: % Invalid command at '^' marker. ! !Flash: disk0: % Invalid command at '^' marker. ! !Flash: slot1: % Invalid command at '^' marker. ! !Flash: disk1: % Invalid command at '^' marker. ! !Flash: slot2: % Invalid command at '^' marker. ! !Flash: disk2: % Invalid command at '^' marker. ! !Flash: harddisk: % Invalid command at '^' marker. ! !Flash: harddiska: % Invalid command at '^' marker. ! !Flash: harddiskb: % Invalid command at '^' marker. ! !Flash: sup-bootdisk: % Invalid command at '^' marker. ! !Flash: sup-microcode: % Invalid command at '^' marker. ! !Flash: slavenvram: % Invalid command at '^' marker. ! !Flash: slavebootflash: % Invalid command at '^' marker. ! !Flash: slaveslot0: % Invalid command at '^' marker. ! !Flash: slavedisk0: % Invalid command at '^' marker. ! !Flash: slaveslot1: % Invalid command at '^' marker. ! !Flash: slavedisk1: % Invalid command at '^' marker. ! !Flash: slaveslot2: % Invalid command at '^' marker. ! !Flash: slavedisk2: % Invalid command at '^' marker. ! !Flash: slavesup-bootflash: % Invalid command at '^' marker. ! !Flash: sec-nvram: % Invalid command at '^' marker. ! !Flash: sec-bootflash: % Invalid command at '^' marker. ! !Flash: sec-slot0: % Invalid command at '^' marker. ! !Flash: sec-disk0: % Invalid command at '^' marker. ! !Flash: sec-slot1: % Invalid command at '^' marker. ! !Flash: sec-disk1: % Invalid command at '^' marker. ! !Flash: sec-slot2: % Invalid command at '^' marker. ! !Flash: sec-disk2: % Invalid command at '^' marker. ! ! !Slot 1: type 48x1GE + 4x10G Supervisor N3K-C3048TP-1GE, 52 ports !Slot 1: part active, serial * ! !CELL: % Invalid command at '^' marker. ! ! % Invalid command at '^' marker. ! !NAME: "Chassis", DESCR: "Nexus 3048 Chassis" !PID: N3K-C3048TP-1GE !VID: V01 !SN: FOC1717R1K3 !NAME: "Slot 1", DESCR: "48x1GE + 4x10G Supervisor" !PID: N3K-C3048TP-1GE !VID: V01 !SN: FOC171646MN !NAME: "Power Supply 1", DESCR: "Nexus 3048 Chassis Power Supply" !PID: N2200-PAC-400W !VID: V06 !SN: LIT24184DCG !NAME: "Power Supply 2", DESCR: "Nexus 3048 Chassis Power Supply" !PID: N2200-PAC-400W !VID: V06 !SN: LIT24184DFQ !NAME: "Fan 1", DESCR: "Nexus 3048 Chassis Fan Module" !PID: N3K-C3048-FAN-F !VID: V00 ! !VLAN: VLAN Name Status Ports !VLAN: ---- -------------------------------- --------- ------------------------------- !VLAN: 1 default active Eth1/26, Eth1/27, Eth1/28 !VLAN: Eth1/29, Eth1/30, Eth1/31 !VLAN: Eth1/32, Eth1/33, Eth1/34 !VLAN: Eth1/35, Eth1/36, Eth1/37 !VLAN: Eth1/38, Eth1/39, Eth1/40 !VLAN: Eth1/41, Eth1/42, Eth1/43 !VLAN: Eth1/44, Eth1/45, Eth1/47 !VLAN: 12 private-pool active Po1, Po2, Po10, Po11, Po12 !VLAN: Po13, Po14, Po15, Po16, Po17 !VLAN: Po18, Po19, Po20, Po25, Po26 !VLAN: Po27, Eth1/3, Eth1/5, Eth1/7 !VLAN: Eth1/9, Eth1/11, Eth1/13 !VLAN: Eth1/14, Eth1/15, Eth1/16 !VLAN: Eth1/17, Eth1/18, Eth1/23 !VLAN: Eth1/24, Eth1/25, Eth1/46 !VLAN: Eth1/49, Eth1/50, Eth1/51 !VLAN: 14 idrac-pool active Po1, Po2, Po3, Po28, Eth1/1 !VLAN: Eth1/46, Eth1/49, Eth1/50 !VLAN: Eth1/51, Eth1/52 !VLAN: 90 cluster-proxmox active Po1, Po2, Po4, Po5, Po6, Po7 !VLAN: Po8, Po9, Po24, Eth1/2, Eth1/4 !VLAN: Eth1/6, Eth1/8, Eth1/10, Eth1/12 !VLAN: Eth1/22, Eth1/49, Eth1/50 !VLAN: Eth1/51 !VLAN: 91 Ceph-Cluster active !VLAN: 1554 uplink-02 active Po1, Po2, Po10, Po11, Po21 !VLAN: Po22, Po23, Eth1/3, Eth1/5 !VLAN: Eth1/19, Eth1/20, Eth1/21 !VLAN: Eth1/49, Eth1/50, Eth1/51 !VLAN: VLAN Type Vlan-mode !VLAN: ---- ----- ---------- !VLAN: 1 enet CE !VLAN: 12 enet CE !VLAN: 14 enet CE !VLAN: 90 enet CE !VLAN: 91 enet CE !VLAN: 1554 enet CE !VLAN: Remote SPAN VLANs !VLAN: ------------------------------------------------------------------------------- !VLAN: Primary Secondary Type Ports !VLAN: ------- --------- --------------- ------------------------------------------- ! !STACK: % Ambiguous command at '^' marker. ! ! ! ! !DEBUG: slot 1 !DEBUG: ======= !DEBUG: Debug level is set to Detail !DEBUG: Debug level is set to Minor(1) !DEBUG: L2RIB Enabled Debugs: !DEBUG: default for new sessions logging level: 3 !Command: show running-config !Running configuration last done at: Wed Feb 4 10:57:51 2026 version 9.3(13) Bios:version 5.0.0 hostname HCM-VNPT-HSK-ACS-3048-04 vdc HCM-VNPT-HSK-ACS-3048-04 id 1 limit-resource vlan minimum 16 maximum 4094 limit-resource vrf minimum 2 maximum 4096 limit-resource port-channel minimum 0 maximum 104 limit-resource u4route-mem minimum 128 maximum 128 limit-resource u6route-mem minimum 96 maximum 96 limit-resource m4route-mem minimum 58 maximum 58 limit-resource m6route-mem minimum 8 maximum 8 feature telnet cfs eth distribute feature interface-vlan feature lacp feature vpc feature lldp clock timezone ICT 7 0 clock protocol none vdc 1 no password strength-check username admin password 5 $5$CNXkM0fn$4u9R4JZ2253DPlUx4p.cyXxcCJlk6XkqMFPUqD6kEV5 role network-admin username adminit password 5 $5$To5CSmnE$usdFojoXpL7d4x6jFg74tIVu2jTiJomF0IoPpjPIOh3 role network-operator username adminit passphrase lifetime 99999 warntime 14 gracetime 3 ip domain-lookup service unsupported-transceiver no errdisable detect cause link-flap ip access-list copp-system-acl-eigrp 10 permit eigrp any 224.0.0.10/32 ipv6 access-list copp-system-acl-eigrp6 10 permit eigrp any ff02::a/128 ip access-list copp-system-acl-icmp 10 permit icmp any any ip access-list copp-system-acl-igmp 10 permit igmp any any ip access-list copp-system-acl-ntp 10 permit udp any any eq ntp 20 permit udp any eq ntp any ip access-list copp-system-acl-pimreg 10 permit pim any any ip access-list copp-system-acl-ping 10 permit icmp any any echo 20 permit icmp any any echo-reply ip access-list copp-system-acl-routingproto1 10 permit tcp any gt 1024 any eq bgp 20 permit tcp any eq bgp any gt 1024 30 permit udp any 224.0.0.0/24 eq rip 40 permit tcp any gt 1024 any eq 639 50 permit tcp any eq 639 any gt 1024 70 permit ospf any any 80 permit ospf any 224.0.0.5/32 90 permit ospf any 224.0.0.6/32 ip access-list copp-system-acl-routingproto2 10 permit udp any 224.0.0.0/24 eq 1985 20 permit 112 any 224.0.0.0/24 ip access-list copp-system-acl-snmp 10 permit udp any any eq snmp 20 permit udp any any eq snmptrap ip access-list copp-system-acl-ssh 10 permit tcp any any eq 22 20 permit tcp any eq 22 any ip access-list copp-system-acl-stftp 10 permit udp any any eq tftp 20 permit udp any any eq 1758 30 permit udp any eq tftp any 40 permit udp any eq 1758 any 50 permit tcp any any eq 115 60 permit tcp any eq 115 any ip access-list copp-system-acl-tacacsradius 10 permit tcp any any eq tacacs 20 permit tcp any eq tacacs any 30 permit udp any any eq 1812 40 permit udp any any eq 1813 50 permit udp any any eq 1645 60 permit udp any any eq 1646 70 permit udp any eq 1812 any 80 permit udp any eq 1813 any 90 permit udp any eq 1645 any 100 permit udp any eq 1646 any ip access-list copp-system-acl-telnet 10 permit tcp any any eq telnet 20 permit tcp any any eq 107 30 permit tcp any eq telnet any 40 permit tcp any eq 107 any ipv6 access-list copp-system-acl-v6routingProto2 10 permit udp any ff02::66/128 eq 2029 20 permit udp any ff02::fb/128 eq 5353 30 permit 112 any ff02::12/128 40 permit pim any ff02::d/128 ipv6 access-list copp-system-acl-v6routingproto1 10 permit 89 any ff02::5/128 20 permit 89 any ff02::6/128 30 permit udp any ff02::9/128 eq 521 ip access-list copp-system-dhcp-relay 10 permit udp any eq bootps any eq bootps ip access-list protect-re 65 permit ip 172.16.0.0/16 any 75 permit ip 10.0.0.0/8 any 90 deny ip any 14.225.249.0/24 class-map type control-plane match-any copp-icmp match access-group name copp-system-acl-icmp class-map type control-plane match-any copp-ntp match access-group name copp-system-acl-ntp class-map type control-plane match-any copp-s-arp class-map type control-plane match-any copp-s-bfd class-map type control-plane match-any copp-s-bpdu class-map type control-plane match-any copp-s-dai class-map type control-plane match-any copp-s-default class-map type control-plane match-any copp-s-dhcpreq class-map type control-plane match-any copp-s-dhcpresp match access-group name copp-system-dhcp-relay class-map type control-plane match-any copp-s-dpss class-map type control-plane match-any copp-s-eigrp match access-group name copp-system-acl-eigrp match access-group name copp-system-acl-eigrp6 class-map type control-plane match-any copp-s-glean class-map type control-plane match-any copp-s-igmp match access-group name copp-system-acl-igmp class-map type control-plane match-any copp-s-ipmcmiss class-map type control-plane match-any copp-s-l2switched class-map type control-plane match-any copp-s-l3destmiss class-map type control-plane match-any copp-s-l3mtufail class-map type control-plane match-any copp-s-l3slowpath class-map type control-plane match-any copp-s-mpls class-map type control-plane match-any copp-s-pimautorp class-map type control-plane match-any copp-s-pimreg match access-group name copp-system-acl-pimreg class-map type control-plane match-any copp-s-ping match access-group name copp-system-acl-ping class-map type control-plane match-any copp-s-ptp class-map type control-plane match-any copp-s-routingProto1 match access-group name copp-system-acl-routingproto1 match access-group name copp-system-acl-v6routingproto1 class-map type control-plane match-any copp-s-routingProto2 match access-group name copp-system-acl-routingproto2 class-map type control-plane match-any copp-s-selfIp class-map type control-plane match-any copp-s-ttl1 class-map type control-plane match-any copp-s-v6routingProto2 match access-group name copp-system-acl-v6routingProto2 class-map type control-plane match-any copp-s-vxlan class-map type control-plane match-any copp-snmp match access-group name copp-system-acl-snmp class-map type control-plane match-any copp-ssh match access-group name copp-system-acl-ssh class-map type control-plane match-any copp-stftp match access-group name copp-system-acl-stftp class-map type control-plane match-any copp-tacacsradius match access-group name copp-system-acl-tacacsradius class-map type control-plane match-any copp-telnet match access-group name copp-system-acl-telnet policy-map type control-plane copp-system-policy class copp-s-default police pps 400 class copp-s-l2switched police pps 200 class copp-s-ping police pps 100 class copp-s-l3destmiss police pps 100 class copp-s-glean police pps 500 class copp-s-selfIp police pps 500 class copp-s-l3mtufail police pps 100 class copp-s-ttl1 police pps 100 class copp-s-ipmcmiss police pps 400 class copp-s-l3slowpath police pps 100 class copp-s-dhcpreq police pps 300 class copp-s-dhcpresp police pps 300 class copp-s-dai police pps 300 class copp-s-igmp police pps 400 class copp-s-eigrp police pps 200 class copp-s-pimreg police pps 200 class copp-s-pimautorp police pps 200 class copp-s-routingProto2 police pps 1300 class copp-s-v6routingProto2 police pps 1300 class copp-s-routingProto1 police pps 1000 class copp-s-arp police pps 200 class copp-s-ptp police pps 1000 class copp-s-vxlan police pps 1000 class copp-s-bfd police pps 350 class copp-s-bpdu police pps 12000 class copp-s-dpss police pps 1000 class copp-s-mpls police pps 100 class copp-icmp police pps 200 class copp-telnet police pps 500 class copp-ssh police pps 500 class copp-snmp police pps 500 class copp-ntp police pps 100 class copp-tacacsradius police pps 400 class copp-stftp police pps 400 control-plane service-policy input copp-system-policy snmp-server user admin network-admin auth md5 040E1558AD04A7BB168E6519D0F92B755CE2 priv 366F6E20D05FD8C423851974A02FBBFEA3F5 localizedV2key snmp-server user adminit network-operator auth md5 5213B242B11563BAE105C3A747541608F1FD priv 482F9571DF6350D8A55AFDB65A0F2C1FFCEA localizedV2key rmon event 1 log trap public description FATAL(1) owner PMON@FATAL rmon event 2 log trap public description CRITICAL(2) owner PMON@CRITICAL rmon event 3 log trap public description ERROR(3) owner PMON@ERROR rmon event 4 log trap public description WARNING(4) owner PMON@WARNING rmon event 5 log trap public description INFORMATION(5) owner PMON@INFO snmp-server community daihuu group network-operator vlan 1 vlan 12 name private-pool vlan 14 name idrac-pool vlan 90 name cluster-proxmox vlan 91 name Ceph-Cluster vlan 1554 name uplink-02 spanning-tree vlan 12,14,90 priority 53248 spanning-tree vlan 1554 priority 61440 vrf context keepalive vrf context management no port-channel load-balance resilient vpc domain 1 peer-switch role priority 65000 peer-keepalive destination 192.168.100.1 source 192.168.100.2 vrf keepalive interface Vlan1 interface Vlan12 no shutdown interface Vlan14 no shutdown ip address 172.16.14.56/24 interface Vlan90 no shutdown interface Vlan1554 no shutdown interface port-channel1 description PO1:TO-HCM-VNPT-ACS-3048-03:PO1#peer-link# switchport mode trunk switchport trunk allowed vlan 12,14,90,1554 spanning-tree port type network vpc peer-link interface port-channel2 description PO2:TO-HCM-VNPT-ACS-3048-02-CI30:PO2 switchport mode trunk switchport trunk allowed vlan 12,14,90,1554 vpc 2 interface port-channel3 description PO3:HCM-VNPT-HSK-ACS-3750-6-CP28:PO3 switchport access vlan 14 vpc 3 interface port-channel4 description PO4:PVE4-TO-SV-Dell R650xs-CP28-U23:172.16.31.16_idrac_.14.29 switchport access vlan 90 vpc 4 interface port-channel5 description PO5:PVE5-TO-SV-Dell R650xs-CP28-U25:172.16.31.17_idrac_.14.30 switchport access vlan 90 vpc 5 interface port-channel6 description PO6:PVE6-TO-SV-Dell R650xs-CP28-U27:172.16.31.18_idrac_.14.31 switchport access vlan 90 vpc 6 interface port-channel7 description PO7:PVE7-TO-SV-Dell R650xs-CP28-U29:172.16.30.19_idrac_.14.32 switchport access vlan 90 vpc 7 interface port-channel8 description PO8:PVE8-TO-SV-Dell R650xs-CP28-U31:172.16.30.20_idrac_.14.33 switchport access vlan 90 vpc 8 interface port-channel9 description PO9:PVE9-TO-SV-Dell R650xs-CP28-U33:172.16.30.21_idrac_.14.34 switchport access vlan 90 vpc 9 interface port-channel10 description PO10:PVE4-TO-SV-Dell R650xs-CP28-U23:172.16.31.16_idrac_.14.29 switchport mode trunk switchport trunk allowed vlan 12,1554 vpc 10 interface port-channel11 description PO11:PVE5-TO-SV-Dell R650xs-CP28-U25:172.16.31.17_idrac_.14.30 switchport mode trunk switchport trunk allowed vlan 12,1554 vpc 11 interface port-channel12 description PO12:PVE6-TO-SV-Dell R650xs-CP28-U27:172.16.31.18_idrac_.14.31 switchport mode trunk switchport trunk allowed vlan 12 vpc 12 interface port-channel13 description PO13:PVE7-TO-SV-Dell R650xs-CP28-U29:172.16.30.19_idrac_.14.32 switchport mode trunk switchport trunk allowed vlan 12 vpc 13 interface port-channel14 description PO14:PVE8-TO-SV-Dell R650xs-CP28-U31:172.16.30.20_idrac_.14.33 switchport mode trunk switchport trunk allowed vlan 12 vpc 14 interface port-channel15 description PO15:PVE9-TO-SV-Dell R650xs-CP28-U33:172.16.30.21_idrac_.14.34 switchport mode trunk switchport trunk allowed vlan 12 vpc 15 interface port-channel16 description PO16:TO-SV-Dell R640-CP28-U21:10.10.12.147_idrac_.14.27 switchport access vlan 12 vpc 16 interface port-channel17 description PO17:TO-SV-Dell R750-CP28-U18-19:10.10.12.190_idrac_.14.28 switchport access vlan 12 vpc 17 interface port-channel18 description PO18:TO-SV-Dell R640-CP28-U12:10.10.12.110_idrac_.14.37 switchport access vlan 12 vpc 18 interface port-channel19 description PO19:TO-SV-Dell R640-CP28-U14:10.10.12.109_idrac_.14.36 switchport access vlan 12 vpc 19 interface port-channel20 description PO20:TO-SV-Dell R640-CP28-U16:10.10.12.108_idrac_.14.35 switchport access vlan 12 vpc 20 interface port-channel21 description PO21:TO-SERVER-U12-CP28:LAN3|Vlan12#IDRAC-172.16.14.37#10.10.12.110/24 switchport access vlan 1554 vpc 21 interface port-channel22 description PO22:TO-SERVER-U14-CP28:LAN3|Vlan12#IDRAC-172.16.14.36#10.10.12.109/24 switchport access vlan 1554 vpc 22 interface port-channel23 description PO23:TO-SERVER-U16-CP28:LAN3|Vlan12#IDRAC-172.16.14.35#10.10.12.108/24 switchport access vlan 1554 vpc 23 interface port-channel24 description PO24:PVE10-TO-SV-CP28-U15#Vlan90_idrac_.14.44 switchport access vlan 90 vpc 24 interface port-channel25 description PO25:TO-Server-CS32-U22-23:idrac_.14.44 switchport access vlan 12 vpc 25 interface port-channel26 description PO26:TO-Server-CS32-U27-28#IDRAC_14.46 switchport access vlan 12 vpc 26 interface port-channel27 description PO27:TO-Server-CS32-U25-26:idrac_.14.45 switchport access vlan 12 vpc 27 interface port-channel28 description PO28:HCM-VNPT-HSK-HP-IDRAC-3-CS32-U29:PO1 switchport mode trunk switchport trunk allowed vlan 14 vpc 28 interface Ethernet1/1 description E1/1-PO3:HCM-VNPT-HSK-ACS-3750-6-CP28:E1/2-P01 switchport access vlan 14 channel-group 3 mode active interface Ethernet1/2 description E1/2-PO4:PVE4-TO-SV-Dell R650xs-CP28-U23-LAN-1:172.16.31.16_idrac_.14.29 switchport access vlan 90 interface Ethernet1/3 description E1/3-PO10:PVE4-TO-SV-Dell R650xs-CP28-U23-LAN-3:172.16.31.16_idrac_.14.29 switchport mode trunk switchport trunk allowed vlan 12,1554 channel-group 10 mode active interface Ethernet1/4 description E1/4-PO5:PVE5-TO-SV-Dell R650xs-CP28-U25-LAN-1:172.16.31.17_idrac_.14.30 switchport access vlan 90 interface Ethernet1/5 description E1/5-PO11:PVE5-TO-SV-Dell R650xs-CP28-U25-LAN-3:172.16.31.17_idrac_.14.30 switchport mode trunk switchport trunk allowed vlan 12,1554 channel-group 11 mode active interface Ethernet1/6 description E1/6-PO6:PVE6-TO-SV-Dell R650xs-CP28-U27-LAN-1:172.16.31.18_idrac_.14.31 switchport access vlan 90 interface Ethernet1/7 description E1/7-PO12:PVE6-TO-SV-Dell R650xs-CP28-U27-LAN-3:172.16.31.18_idrac_.14.31 switchport mode trunk switchport trunk allowed vlan 12 channel-group 12 mode active interface Ethernet1/8 description E1/8-PO7:PVE7-TO-SV-Dell R650xs-CP28-U29-LAN-1:172.16.30.19_idrac_.14.32 switchport access vlan 90 interface Ethernet1/9 description E1/9-PO13:PVE7-TO-SV-Dell R650xs-CP28-U29-LAN-3:172.16.30.19_idrac_.14.32 switchport mode trunk switchport trunk allowed vlan 12 channel-group 13 mode active interface Ethernet1/10 description E1/10-PO8:PVE8-TO-SV-Dell R650xs-CP28-U31-LAN-1:172.16.30.20_idrac_.14.33 switchport access vlan 90 interface Ethernet1/11 description E1/11-PO14:PVE8-TO-SV-Dell R650xs-CP28-U31-LAN-3:172.16.30.20_idrac_.14.33 switchport mode trunk switchport trunk allowed vlan 12 channel-group 14 mode active interface Ethernet1/12 description E1/12-PO9:PVE9-TO-SV-Dell R650xs-CP28-U33-LAN-1:172.16.30.21_idrac_.14.34 switchport access vlan 90 interface Ethernet1/13 description E1/13-PO15:PVE9-TO-SV-Dell R650xs-CP28-U33-LAN-3:172.16.30.21_idrac_.14.34 switchport mode trunk switchport trunk allowed vlan 12 channel-group 15 mode active interface Ethernet1/14 description E1/14-PO16:TO-SV-Dell R640-CP28-U21-LAN-1:10.10.12.147_idrac_.14.27 switchport access vlan 12 channel-group 16 mode active interface Ethernet1/15 description E1/15-PO17:TO-SV-Dell R750-CP28-U18-19-LAN-1:10.10.12.190_idrac_.14.28 switchport access vlan 12 channel-group 17 mode active interface Ethernet1/16 description E1/16-PO18:TO-SV-Dell R640-CP28-U12-LAN-1:10.10.12.110_idrac_.14.37 switchport access vlan 12 channel-group 18 mode active interface Ethernet1/17 description E1/17-PO19:TO-SV-Dell R640-CP28-U14-LAN-1:10.10.12.109_idrac_.14.36 switchport access vlan 12 channel-group 19 mode active interface Ethernet1/18 description E1/18-PO20:TO-SV-Dell R640-CP28-U16-LAN-0:10.10.12.108_idrac_.14.35 switchport access vlan 12 channel-group 20 mode active interface Ethernet1/19 description E1/19-PO21:TO-SERVER-U12-CP28:LAN3|Vlan12#IDRAC-172.16.14.37#10.10.12.110/24 switchport access vlan 1554 channel-group 21 mode active interface Ethernet1/20 description E1/20-PO22:TO-SERVER-U14-CP28:LAN3|Vlan12#IDRAC-172.16.14.36#10.10.12.109/24 switchport access vlan 1554 channel-group 22 mode active interface Ethernet1/21 description E1/21-PO23:TO-SERVER-U16-CP28:LAN3|Vlan12#IDRAC-172.16.14.35#10.10.12.108/24 switchport access vlan 1554 channel-group 23 mode active interface Ethernet1/22 description E1/22-PO24:PVE10-TO-SV-CP28-U15-LAN-1#Vlan90_idrac_.14.44 switchport access vlan 90 interface Ethernet1/23 description E1/23-PO25:TO-Server-CS32-U22-23-LAN-1:idrac_.14.44 switchport access vlan 12 channel-group 25 mode active interface Ethernet1/24 description E1/24-PO26:TO-Server-CS32-U27-28-LAN-1#IDRAC_14.46 switchport access vlan 12 channel-group 26 mode active interface Ethernet1/25 description E1/25-PO27:TO-Server-CS32-U25-26-LAN-1:idrac_.14.45 switchport access vlan 12 channel-group 27 mode active interface Ethernet1/26 interface Ethernet1/27 interface Ethernet1/28 interface Ethernet1/29 interface Ethernet1/30 interface Ethernet1/31 interface Ethernet1/32 interface Ethernet1/33 interface Ethernet1/34 interface Ethernet1/35 interface Ethernet1/36 interface Ethernet1/37 interface Ethernet1/38 interface Ethernet1/39 interface Ethernet1/40 interface Ethernet1/41 interface Ethernet1/42 interface Ethernet1/43 interface Ethernet1/44 interface Ethernet1/45 interface Ethernet1/46 description E1/46-PO24:TO-HCM-VNPT-HSK-FW-01:GE-7/0/0-RETH3 switchport mode trunk switchport trunk allowed vlan 12,14 interface Ethernet1/47 interface Ethernet1/48 description E1/48:TO-HCM-VNPT-ACS-3048-03:E1/48#keepalive-link# no switchport vrf member keepalive ip address 192.168.100.2/24 interface Ethernet1/49 description E1/49-PO1:TO-HCM-VNPT-ACS-3048-03:E1/49-PO1#peer-link# switchport mode trunk switchport trunk allowed vlan 12,14,90,1554 channel-group 1 mode active interface Ethernet1/50 description E1/50-PO1:TO-HCM-VNPT-ACS-3048-03:E1/50-PO1#peer-link# switchport mode trunk switchport trunk allowed vlan 12,14,90,1554 channel-group 1 mode active interface Ethernet1/51 description E1/51-PO2:TO-HCM-VNPT-ACS-3048-02-CI30:E1/50-P041|Network switchport mode trunk switchport trunk allowed vlan 12,14,90,1554 channel-group 2 mode active interface Ethernet1/52 description E1/52-PO28:HCM-VNPT-HSK-HP-IDRAC-3-CS32-U29:E1/50-P01 switchport mode trunk switchport trunk allowed vlan 14 channel-group 28 mode active interface mgmt0 vrf member management line console line vty access-class protect-re in boot nxos bootflash:/nxos.9.3.13_compact.bin